<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>step</ParameterFamily>
<LongName>
away_limit_source
</LongName>
<Name>
als
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Platesetter_VLF</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
The away limit signal source.
</text></DescriptionText>
</Description>
<Type>
unsigned integer
</Type>
<Default>
<UnnumberedList>
<li>0x50</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 254</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
0 : stepper CCW signal
2: stepper CW signal
4: stepper home limit signal
8: stepper away limit signal
16: stepper board A switch signal
32: stepper board B switch signal
64: stepper board A bay signal
128: stepper board B Bay signal
Numbers which do not appear on the list are the logically OR'd sum of numbers from the list.
For example:
112	=64+32+16 = stepper board A bay signal OR stepper board B switch signal OR stepper board A switch signal.
These are set up during machine integration and should not require changes.
The actual meaning of each signal is defined by the hardware associated with each step axis and is different for each step axis.
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:38 2008 PST
</Updated>
<Links>
</Links>
</Parameter>